A list of local fire and rescue agencies is available from the county administrators office 540 473 8233.
Minimum gate width for fire truck.
The access road may be reduced to 12 of unobstructed width with a minimum 10 wide driving surface for 1 3 parcels or building sites on approval of the fire marshal and plfr.
Minimum building access for fire apparatus is a function of the access road reaching to within a certain distance of all portions of the building s first floor exterior walls.
Minimum standards for security gates gates shall not reduce the required roadway width to less than the minimum width required by the fire department 20 ft.
Perimeter security points e g.
Gates shall be of the swinging or sliding type.
Width a large fire truck requires a minimum road width of 10 feet.
90 gpm 100 psi minimum cafs solution water flow.
The minimum clear width of fire department access roads shall be 20 feet 6 096 mm.
10 a fire apparatus access road sh all be a minimum unobstructed width of 20 for commercial structures or 4 or more parcels or building sites.
Sliding swinging gates boom gates bollards vehicle security barriers must not make it difficult for appliances to gain access.
Where a single gate is provided the gate width shall be not less than 20 feet 6096 mm.
At least 2 feet wider than fire lanes.
75 000 pounds 34 050 kg or as otherwise determined by the fire code official.
A 20 foot width with hard shoulders.
Free and clear see attachment.
Even with a road this width no other vehicles can pass when a large fire truck is traveling the road.
Alternate designs may be approved on a case by case basis.
This width may be increased based upon specific department operations and or apparatus.
20 gpm for a 1 inch cafs discharge.
Accessway should be constructed of an all weather surface e g.
Adequate stacking lane shall be provided based on the projected volume of traffic for the project.
In addition to the minimum standards and specifications for small brush trucks large brush trucks and tankers described above the following minimum standards are required for cafs equipped vehicles and slip on modules.
Where a fire apparatus road consists of a divided roadway the gate width shall be not less than 12 feet 3658 mm.
Gates securing the fire apparatus access roads shall comply with all of the following criteria.
Measures to gain access.
Water pump minimum water pump capacity.
A minimum width of 3 5 m and height of 4 m should be provided at site entrances internal entrances and between buildings.